SIGA UTS320

SIGA UTS320

Product Code: SIGA UTS320
Availability:
Pre-Order
Description

Equipment:

UTS– smoke tube boilers, where water circulates between the steel walls of the furnace and the pipes. The outer surface is insulated with a layer of mineral wool. The quantity of air is automatically controlled by thermostatic draft regulator. Boilers are designed for the heating of industrial, domestic, administrative and other rooms, where the central heating system is installed. Water circulation in a boiler and the system is forced.The boilers have been awarded certificates by European Union. They fire solid fuel: wood, chips, sawdust briquettes, pellets, coal, etc.

Boiler can be equipped with automatic biomass burners:

 

TECHNICAL PROFILE

 

TYPE OF BOILER

 

UTS-100

UTS-150

UTS-200

UTS-250

UTS-320

UTS-500

Thermal power,kW±7%,

-burning coal (calorific value is not less than 29,880 MJ/kg)

100

150

200

250

350

500

-burning not wetter than 20% of moisture content wood

87

131

175

220

310

440

Efficiency factor, %

 

 

74...82

 

 

Water temperature in a boiler,

C

 

 

 

 

 

 

-returning, at least -given, at least

 

 

 

     65

     95

 

 

Water pressure in the boiler not more than, MPa

0,4

Water circutalion in a boiler

forced

Water capacity in a boiler, 1

342

469

616

683

1065

863

Area of the boiler heating surfaces, m2

7,6

11,4

14,7

18,0

25,8

32,0

Affinity behind a boiler, Pa

28

34

40

46

58

68

Flue smoke gas temperature,

C

250

Fuel type, preparation and use:

hard lump fuel

-coal (calorific calue is not less

thickness of layer, mm

50...200

than 29,88MJ/kg)

use kg/h

14,8

2

29,6

37,0

51,8

74.0

-dry up to 20% of humidity, and not

height of charge, mm

200...350

more 0 130 chopped wood

use, kg/h

19,3

29,0

38,6

48,2

67,6

96,5

Reference heated floor space (building thermal resistance is not less than 2,5 m2 kW

 

 

 

 

 

 

Overall dimentions, mm -length -height -width

1390

1950

700

1620

1950

800

1850

1950

950

2050

1950

1000

2150

2160

1220

3275

2340

1860

Furnance depth / maximum length of wood, mm

946/800

1146/1100

1346/1300

1546/1400

1536/1400

1800/1700

Service time until, years

10

Boiler mass, kg

810

1070

1330

1650

1950

2500

Electrical profile: -voltage and frequency

220v; 50 Hz

-use of power

 

0,26

 

 

0,47

 

-degree of protection

IP 44

Recirculating pump and fan control

manual and automatic

Tags:
Tags: SIGA

Related Products

SIGA GROUP UAB © 2024